saturated calomel electrode kit
saturated calomel electrode kit pipette
saturated calomel electrode kit solution
saturated calomel electrode kit manual
saturated calomel electrode diagram
saturated calomel electrode kit
saturated calomel electrode kit
saturated calomel electrode kit
saturated calomel electrode kit contents
Universal Size SCE
saturated calomel electrode kit contents
Tapered 12 size SCE
Skinny size SCE
saturated calomel electrode kit
saturated calomel electrode kit
  • Load image into Gallery viewer, saturated calomel electrode kit
  • Load image into Gallery viewer, saturated calomel electrode kit pipette
  • Load image into Gallery viewer, saturated calomel electrode kit solution
  • Load image into Gallery viewer, saturated calomel electrode kit manual
  • Load image into Gallery viewer, saturated calomel electrode diagram
  • Load image into Gallery viewer, saturated calomel electrode kit
  • Load image into Gallery viewer, saturated calomel electrode kit
  • Load image into Gallery viewer, saturated calomel electrode kit
  • Load image into Gallery viewer, saturated calomel electrode kit contents
  • Load image into Gallery viewer, Universal Size SCE
  • Load image into Gallery viewer, saturated calomel electrode kit contents
  • Load image into Gallery viewer, Tapered 12 size SCE
  • Load image into Gallery viewer, Skinny size SCE
  • Load image into Gallery viewer, saturated calomel electrode kit
  • Load image into Gallery viewer, saturated calomel electrode kit

Saturated Calomel Electrode Kit (1001 Series)

Vendor
Koslow Scientific
Regular price
$380.00
Sale price
$380.00
Regular price
Sold out
Unit price
per 
Shipping calculated at checkout.


 

The Saturated Calomel Reference Electrode can also be known as Mercury/ Mercurous Chloride, or simply the S.C.E. Mercury (I) chloride is a chemical compound with the formula Hg₂Cl₂ (also known as the mineral calomel or mercurous chloride). For laboratory use, the Koslow S.C.E. has excellent ion transfer and low noise.

Reference Electrode Potential:

  • 244 mV vs. Normal Hydrogen Electrode (NHE)
  • 410 mV vs. Mercury Sulfate Reference Electrode (M.S.E.)
  • 440 mV vs. Silver / Silver Sulfate

APPLICATIONS:

  • Electro-analysis
  • Battery maintenance & testing
  • Corrosion testing
  • Electro-Analytical studies

 STEPS TO VERIFY VIABILITY OF ELECTRODE:

  1. Create a ~5mm layer of electrode solution in a beaker
  2. Place two electrodes of the same type into the pool of solution
  3. Compare the readings using a volt meter
  4. If they are within 10 mV of variation, it is good to go!

FEATURES:

  • Carry Case
  • Electrode Refill Solution Electrolyte 30 ml
  • Laboratory Electrode Storage Bottle
  • 2-Pack of Replacement Porous Tips
  • 2 Heat Shrinkable Sleeves
  • Electrode Filling Pipette
  • Absorbent Foam
  • Maintenance Manual